{"affected": [{"affectedData": [{"defaultStatus": "unaffected", "product": "EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Version 11.06.31 and prior"}]}, {"defaultStatus": "unaffected", "product": "Saitel DP Remote Terminal Unit & Controller", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Version 11.06.37 and prior"}]}], "source": "
[email protected]"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:easylogic_t150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D498A9B-1593-41C1-BB95-F7815F01087D", "versionEndExcluding": "11.06.32", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:easylogic_t150:-:*:*:*:*:*:*:*", "matchCriteriaId": "E3B30463-195D-4D26-BC9E-9BA0D9BBB862", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:saitel_dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "71B582C0-A3F2-4E6F-B2CE-E77ACB81F59F", "versionEndExcluding": "11.06.38", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:saitel_dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6D73382-1957-4CC7-953F-D57C005D63B0", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files."}], "id": "CVE-2026-9651", "lastModified": "2026-07-14T16:00:32.253", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.1"}, "exploitabilityScore": 0.8, "impactScore": 3.6, "source": "
[email protected]", "type": "Primary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "availabilityRequirement": "NOT_DEFINED", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "HIGH", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "
[email protected]", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2026-9651", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "partial"}], "role": "CISA Coordinator", "timestamp": "2026-06-25T15:49:29.524994Z", "version": "2.0.3"}}]}, "published": "2026-06-25T16:16:43.990", "references": [{"source": "
[email protected]", "tags": ["Vendor Advisory"], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf"}], "sourceIdentifier": "
[email protected]", "vulnStatus": "Analyzed", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-732"}], "source": "
[email protected]", "type": "Secondary"}]}